Two Annual tips to keep your water well system happy!!

 

Disinfecting a Well

1.       Remove the well cover.  Pour the required amount of bleach as prescribed by Roarke Well Drilling, Inc..

2.      Connect garden hose to an outside tap.  Put other end of the hose into the well, turn on faucet, and from time to time move the hose so that the chlorinated water bathes the sidewalls of the well. Do this for at least 4 hours, preferably over night.

3.      After the minimum 4 hours of circulation, run all faucets in the house, one at a time, until you smell chlorine at each faucet.  This ensures that the whole system gets disinfected.  Hot, cold, inside and outside faucets.

4.      After circulating chlorinated water back into well for the four hours, (prefer over night) shut off faucet, remove hose from well casing, and replace well cap.

5.      Don’t use the water for at least 12 hours.  Forty-eight hours is optimal.

6.      After a minimum of 12 hours, run the water to waste, but not into the septic system, for several hours, or until the chlorine smell and taste is gone.

7.      To avoid over pumping a weak well or over heating the pump, turn off water when flow is at a trickle and wait at least 1 hour before resuming.

8.      Test for bacteria after a week of use.

9.      In some cases, one chlorination will not be sufficient.  Repeat disinfecting procedure as needed.

 

Required amount of chlorine for this well is 1 gallon for every 100 foot of water in well.

 

Checking the Captive Air Tank

1.      Note your operating pressure of well system. (pump on 30 psi / off 50 psi or on 40 psi / off 60 psi)

2.      Turn off power to pump and drain the Captive Air Tank. (tank should feel light and wiggle easily)

3.      With an accurate tire gauge, check air in tank at the tire valve. (Usually on top of tank)

4.      Air pressure, when tank is empty of water, should be two (2) psi less than pump on psi setting.  Ex. Pump running at 40/60 should have 38 psi of air in it.

5.      If air pressure is lower or higher than the correct amount adjust accordingly.

 

Thank you for allowing us to assist you.  If you need assistance just call me and I will help you.

 

 